Panasonic KX-TDA50 Pc Programming Manual page 266

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

4.4 [2-3] Timers & Counters
Feature Manual References
None
During Conversation—Pause Signal Time
Specifies the length of the pause inserted when the PAUSE button is pressed during a conversation.
Default
1.5 s
Value Range
1.5 s, 2.5 s, 3.5 s, 4.5 s
Maintenance Console Location
4.4 [2-3] Timers & Counters
Programming Manual References
None
Feature Manual References
13.1.4 Pause Insertion
System Wireless—PS Out of Range Timer
When the destination of an incoming call is a PS, specifies the length of time the PBX searches for the PS
before setting its status to Out of Range.
If "0" is assigned, the timer is controlled by the cell station.
Default
0 s
Value Range
0 s, 4 s, 8 s
Maintenance Console Location
4.4 [2-3] Timers & Counters
Programming Manual References
4.17 [2-9] System Options—
Feature Manual References
13.1.17 Private Network Features—PS Roaming by Network ICD Group
266
PC Programming Manual
System Wireless—Out of Range Registration
Document Version 2010-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda600Kx-tda200Kx-tda100

Table of Contents