Mode when Dial Time-out before TRS Check
Selects whether a CO line is disconnected if the TRS check has not been completed when the CO line
Inter-digit timer expires.
Default
Disconnect
Value Range
Disconnect: The CO line is disconnected as soon as the timer expires.
Keep: The TRS check is performed when the timer expires.
Maintenance Console Location
9.5 [7-5] Miscellaneous
Programming Manual References
4.4 [2-3] Timers & Counters
Feature Manual References
17.1.6 TRS (Toll Restriction)
Dial Digits Limitation After Answering—Dial Digits
Specifies a limit to be placed on the number of digits which can be dialed after an extension user receives a
CO line call. If the number of dialed digits exceeds the programmed limit, the line will be disconnected.
Default
None
Value Range
None, 1–7
Maintenance Console Location
9.5 [7-5] Miscellaneous
Programming Manual References
None
Feature Manual References
17.1.6 TRS (Toll Restriction)
3.1.15 CO Line Call Limitation
TRS Check after EFA
Enables TRS to check the digits dialed after External Feature Access (EFA) during a CO line call.