Panasonic KX-TDA50 Pc Programming Manual page 123

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

Value Range
0–600 ´ 100 ms
Maintenance Console Location
3.13 [1-1] Slot—Card Property - PRI type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
ISDN CO / QSIG Master / QSIG Slave—T303
Specifies the maximum time that the PBX waits for a reply after sending the SETUP (call setting) message to
ISDN.
Default
40 ´ 100 ms
Value Range
0–600 ´ 100 ms
Maintenance Console Location
3.13 [1-1] Slot—Card Property - PRI type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
ISDN CO / QSIG Master / QSIG Slave—T304
Specifies the maximum time allowed between each digit on an outgoing call. Applies to overlap sending.
Default
300 ´ 100 ms
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.13 [1-1] Slot—Card Property - PRI type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Document Version 2010-11
3.13 [1-1] Slot—Card Property - PRI type (KX-TDA100/KX-TDA200/KX-TDA600 only)