To change the value displayed here, click Common Settings, and set the desired value for
Address.
Default
0.0.0.0
Value Range
0.0.0.0–223.255.255.255
Maintenance Console Location
3.22 [1-1] Slot—Card Property - IP Extension
Programming Manual References
3.23 [1-1] Slot—Card Property - IP Extension—Common Settings
Feature Manual References
9.1.15 IP-PT (IP Proprietary Telephone)
Keep Alive Time Out
Specifies the length of time that the PBX will continue to consider an IP-PT to be active even if it receives no
transmissions from that IP-PT. The PBX constantly confirms the status of IP-PTs. If no communications are
received from an IP-PT for the duration specified here, the PBX considers the IP-PT to be unreachable, and
sets the port status to Fault.
During operation, set between 10 s and 60 s. Settings over 60 s, and Disable, are used for debugging purposes,
and IP-PTs cannot be guaranteed to function normally in these circumstances. Do not use debugging settings
unless instructed to do so.
Default
10 s
Value Range
Disable, 10–120 s
Maintenance Console Location
3.22 [1-1] Slot—Card Property - IP Extension
Programming Manual References
None
Feature Manual References
9.1.15 IP-PT (IP Proprietary Telephone)
Echo Canceller Ability
Specifies the echo canceler ability time.
Document Version 2010-11
3.22 [1-1] Slot—Card Property - IP Extension
PC Programming Manual
Gateway
191