Electrical Specifications; Environmental Specifications - Nortel 114200-E Installation And Operating

Passport arn routers
Table of Contents

Advertisement

Installing and Operating Passport ARN Routers
If you are installing your ARN in an electronic equipment rack, make sure that the
rack meets the following specifications:
Heavy-duty steel construction
Electronic Industries Association (EIA) standard hole-spacing
Width of 19 in. (48.26 cm)
Depth of 24 in. (60.96 cm)

Electrical Specifications

Your installation site must meet the following power requirements:
Proximity to wall receptacle: within 6 ft (1.8 m) of the ARN
Voltage: 100 to 240 VAC
Amperage: 0.5 to 1.0 A
Table C-1
Table C-1.
Country
United States/
Canada
Any other country Your ARN distributor informs you of the

Environmental Specifications

The environmental requirements of the ARN are as follows:
Altitude: 0 to 8,000 ft (0 to 2,438.4 m)
Humidity: 10% to 90%, noncondensing
Temperature: 32°F to 104°F (0°C to 40°C) stable
C-2
lists the wall outlet requirements.
ARN Wall Outlet Requirements
Outlet
National Electrical Manufacturers
Association (NEMA) 5-15P standard outlet
outlet you need.
Voltage
100 to 120 V
200 to 240 V