Electrical system
Description: Oil pressure failure. Error code: DSB 08
The instrument panel keeps all previous errors stored in its memory.
DELETE ERRORS
This option deletes instrument panel errors only, a further confirmation is requested.
INSTRUMENT PANEL SOFTWARE UPGRADE
This function is used to program the instrument
panel again with a new software through Naviga-
tor.
The Display reads: "Instrument panel disconnec-
ted. Now connect the diagnosis instrument"; the
instrument panel will connect normally after the
key is extracted-inserted.
The white connector is placed under the saddle,
beside the fuse box, close to the diagnosis con-
nector for the injection system.
Use the Ditech connector in the Navigator Aprilia-
Moto Guzzi package to connect to the Navigator
cable.
KEY CHANGE FUNCTION
This function can be used:
1) if one key is lost; the dealer can disable this key;
2) to activate up to 4 keys;
3) should a new key lock be necessary and thus program the new set of keys.
In the first phase the user code must be entered and, after confirming the inserted key (key I) has been
programmed, the other keys must be entered too.
The procedure finishes once the 4 keys have been programmed or after 20 seconds.
Should a new key lock be necessary, the procedure is: once the key is set to ON but the instrument
panel does not recognise it, the user code is requested: enter the user code.
Now enter MENU, DIAGNOSIS (entering the service code), KEY CHANGE and program the new keys.
Battery recharge circuit