MOTO GUZZI stelvio 1200 NTX MY11 Service Manual page 242

Table of Contents

Advertisement

Power supply
ECU INFO screen page
This screen page shows general data regarding
the control unit, for example software type, map-
ping, control unit programming date
Specification
Mapping
PARAMETERS screen page
This screen page shows the parameters meas-
ured by the several sensors (engine revs, engine
temperature, etc.) or values set by the control unit
(injection time, ignition advance, etc.)
Specification
Engine rpm
Injection time
Ignition advance
Air temperature
Engine temperature
Battery voltage
Throttle
Atmospheric pressure
Lambda probe
Lambda integrator
Vehicle speed
P SUPP - 242
Revente Interdite - Revendita Vietata - Resaling Forbiden - Wiederverkauf Verboten
INFO ECU SCREEN PAGE
PARAMETERS SCREEN PAGE
Engine revolutions per minute: the minimum value is set by the
Temperature of the air taken in by the engine, measured by the
sensor in the filter casing. This is not the temperature indicated
Value corresponding to the throttle when closed (approximate
value between 4.5 and 4.9°) (left throttle supported by the end
of stroke screw). If a different value is read, it is necessary to
activate the parameter "Throttle positioner autodetection" and
Signal when energised that the control unit receives from the
lambda probe: inversely proportional to the presence of oxygen
When the control unit uses the lambda probe signal (see the
'Lambda' parameter on the 'Statuses' screen page) this value
Stelvio 1200 NTX MY11
Desc./Quantity
-
Desc./Quantity
control unit cannot be adjusted
- ms
- °
°C
by the instrument panel
°C
V
obtain this value.
1015 mPa (approximate values)
The sensor is inside the instrument panel
100 - 900 mV (approximate values)
should be close to 0%.
- km/h

Hide quick links: