Target engine revs
Stepper base
CL Stepper
Stepper regulator
Virtual throttle angle from Stepper
STATUS screen page
This screen page shows the status (usually ON/
OFF) of the vehicle devices or the operation con-
dition of some vehicle systems (for example, lamb-
da probe functioning status).
Specification
Engine status
Throttle position
Stand
Ignition
RUN / STOP switch
Clutch
Gear engaged
fall sensor
Lambda
Synchronisation
Revente Interdite - Revendita Vietata - Resaling Forbiden - Wiederverkauf Verboten
1150 rpm (approximate values)
Parameter valid at idle, setting depends especially on the en-
gine temperature: the control unit will try to keep the engine
running at this revs, acting on the ignition advance and the
70 - 100 (approximate values)
Steps corresponding to the Stepper motor reference position
70 - 150 (approximate values)
Steps set by the control unit for the Stepper motor. At idle, steps
so that the engine keeps the target engine revs set by the con-
Difference between current steps of motor at idle and those at
the reference position
With engine not at idle speed, this value indicates the throttle
degrees corresponding to the Stepper motor air flow
STATUSES
ON/run/power-latch/stopped
operation conditions
Released / pressed
indicates if the throttle potentiometer is open or closed
Retracted / extended
indicates the position of the side stand (only with gear engaged)
Enabled / disabled
indicates if the control unit consents engine start-up
indicates the position of the safety switch
indicates the clutch sensor status
indicates the gear sensor status
indicates the vehicle fall sensor status
Open loop / Closed loop
Indicates if the control unit is using (CLOSED) the lambda
probe signal to keep the stoichiometric combustion. At idle
CLOSED only if: Air T over 20°C (68°F) and engine T over 30°
C (86°F) and engine on for at least 2-3 minutes
Synchronised / Not synchronised
Indicates if the control unit detects the revolution sensor signal
Power supply
Desc./Quantity
Stepper motor
trol unit
Desc./Quantity
Run / stop
No / Yes
No / Yes
Normal / Tip over
correctly