Controls, connectors and indicators

2
3
Figure 3.7: Top and bottom views of the call station
Controls, indicators and connectors on the call station:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Bosch Security Systems B.V.
Plena
4
Power indicator:
A green LED to indicate that the call station is powered on.
Zone selection buttons:
Six buttons to select the zones to which the business call is distributed (see section
Business calls, page 89). Each button has a green LED, which indicates the zones to
which the business call is distributed.
'All call' button:
A button to select all zones (see section Business calls, page 89).
Push-to-talk button:
A push-to-talk (PTT) button to start the business call.
Status indicators:
Three LEDs that indicate the status of the call station (see section Make the
announcement, page 90).
Keypad connector:
A connector to connect call station keypads to the call station.
Configuration settings:
A set of DIP switches to configure the call station (see section Call station, page 83).
Power supply inlet:
A socket to connect a 24 V(DC) power supply (see section Power supply, page 69).
System sockets:
Two redundant RJ45 sockets to connect the call station to the voice alarm controller (see
section Call station, page 50).