en | Technical data
External power amplifiers
Type:
Router output/Amplifier input:
Router input/Amplifier output:
10.1.3

Call Station

Electrical
Voltage range:
Current consumption:
Performance
Nominal sensitivity:
Nominal output level:
Maximum input sound level:
Gain preset:
Limiter threshold:
Compression ratio limiter:
Distortion:
Equivalent input noise level:
Frequency response:
Speech filter:
Output impedance:
Interconnection
Type:
10.2

Physical characteristics

10.2.1

Voice Alarm Controller

Dimensions:
19" mounting brackets:
Weight:
2013.07 | V2.0 |
Installation and Operation manual
3-pin XLR and screw terminals
1 V
100 V
24 V(DC), +20%/-10%, supplied by the
Controller or external power source
< 30 mA
85 dB SPL (gain preset 0 dB)
355 mV
110 dB SPL
+6/0/-15 dB
2 V
20:1
< 0.6% (nominal input)
< 5% (maximum input)
25 dB SPL(A)
100 Hz - 16 kHz
- 3 dB @ 500 Hz, high-pass, 6 dB/oct
200 Ω
2x redundant RJ45 sockets to connect the
call station to the voice alarm system
controller with CAT‑5 Ethernet cables.
19" wide, 3 U high, 360 mm deep
(leave 50 mm for connections)
Included
Approx. 20 kg
Plena
Bosch Security Systems B.V.