Plena
2.
3.
4.
5.
6.
7.
8.
9.
10. All call button:
11. Indicator test button:
12. Emergency button:
13. Alert message button:
14. Alarm message button:
Bosch Security Systems B.V.
Fault indicators:
Twelve yellow system fault LEDs (Processor reset, Network, Call/EMG, Music/Spare,
Ground short, Input, Mains, Battery, Message, EMG mic, RCP and Router) and twelve
yellow loudspeaker line fault LEDs. Fault indication is only possible if supervision is
enabled (see section Fault indicators, page 98). If supervision is disabled, the yellow
Disabled LED is lit.
Fault state buttons:
Two buttons to acknowledge (Ack) and reset (Reset) the fault state (see section Fault
State, page 96).
Emergency state buttons:
Two buttons to acknowledge (Ack) and reset (Reset) the emergency state (see section
Emergency state, page 91).
Emergency call zone selectors:
Six buttons to select the zones to which the emergency call must be distributed (see
section Emergency state, page 91). Each button has a green and a red LED. The six red
LEDs indicate the zones that are selected for the emergency call. The six green LEDs
indicate the zones in which a business call is running.
BGM zone selectors:
Six buttons to select the zones to which the BGM is distributed (see section Background
music, page 88). Each button has a green LED and a rotary knob. The six green LEDs
indicate the zones to which BGM is distributed. The six rotary knobs are local volume
controls that can be used to adjust the volume of the BGM in each zone. Each volume
control knob has six settings.
BGM master volume control:
A rotary knob to set the master volume of the BGM (see section Background music, page
88).
BGM source selector:
A button to select the BGM source (CD/Tuner or Aux). The selected source is indicated
with a green LED (see section Background music, page 88).
BGM tone controls:
Two rotary knobs to control the high and low frequencies of the BGM (see section
Background music, page 88).
A button to select all zones. This button is only available in the emergency state (see
section Emergency state, page 91).
A button to test all LEDs on the front panel of the voice alarm controller, and connected
voice alarm routers, remote control panels, remote control extensions and fireman's
panels. All LEDs are lit as long as the button is pushed (see section Fault State, page
96).
A push button to put the system in the emergency state (see sectionEmergency state, page
91).
A button to select the alert message. This button is only available in the emergency state
(see section Emergency state, page 91).
A button to select the default alarm message. This button is only available in the
emergency state (see section Emergency state, page 91).
Installation and Operation manual
System overview | en
15
2013.07 | V2.0 |