Controller Operation; Controls/Indicators - Bosch LTC 5136/61 Instruction Manual

Ltc 5136 series autodome controller
Table of Contents

Advertisement

LTC 5136 Series | Instruction Manual | Controller Operation
5. Press ON-1-ENTER and the address is set.
Once the Fast Address is set, the switch address
(thumbwheel) is ignored. The Fast Address is
stored to non-volatile memory, and will not
change if power is removed or factory defaults
are restored (SET-899-ENTER).
To reset the dome's address to the switch
address (thumbwheel), repeat the above
steps and end by pressing OFF-1-ENTER.
To check/confirm the address, call up the
camera and press ON-997-ENTER. This
command causes all cameras to briefly
display their addresses.
6

CONTROLLER OPERATION

Operation is quite simple. If the camera number to be
controlled is not visible in the LED displays, use the
numeric keypad to select the desired camera, then
press ENTER. The camera can now be operated using
the appropriate joystick and/or lens controls. If
appropriate, pre-position scenes and auxiliary functions
can also be entered.
Note that a delay of more than 3-4 seconds while
entering a selection results in the Controller returning
to the default camera entry mode. If this condition
occurs, start the selection again, from the beginning.
A complete description of the controls and indicators is
provided in the next section.
6.1

Controls/Indicators

LED Indicators: The four digit, 7-segment LED display
is used to display data entry and the selected camera
number.
SET key: This key is used to set pre-position scenes of
all AutoDome cameras and Allegiant Series Receiver/
Drivers which are equipped with this option. Operate
the joystick and lens controls to position the camera to
the desired scene to be programmed. Press SET, then
enter the desired pre-position number on the numeric
keypad (1 to 99). Press ENTER to store the position.
Certain pre-position numbers are also used to program
certain AutoDome features. Refer to the AutoDome
operation manual for a complete listing of the available
features.
USER key: Press USER-1-ENTER to enter the
Controller diagnostic mode. This function can be used
Bosch Security Systems | 04 September 2003
to ensure that all Controller LEDs and buttons are in
working order. It also automatically calibrates the
center position of the analog joystick. Upon entering
this mode, the Controller sounds a short beep. The
display readouts and LEDs behind the first two rows of
buttons also illuminate for about two seconds. During
this time, the joystick undergoes calibration, so be
careful not to move it until the LED displays have
gone dark. The operator should note any LED display
failures during the time they are illuminated.
Each key may now be pressed to display a unique
code number associated with that key. Use the table
below to ensure that all keys are operating properly.
Push the USER key last, as this will cause the
Controller to exit the test mode.
Key
Number
Key
Set
0009
9
Camera
0025
0
Shot
0010
Enter
On
0018
Clear
Off
0026
Focus (up)
1
0011
Focus (down)
2
0019
Iris (up)
3
0027
Iris (down)
4
0012
Up
5
0020
Down
6
0028
Left
7
0013
Right
8
0021
Zoom (CW)
Zoom (CCW)
NOTE: The x digit shown in the number column, for
up, down, left, right, and zoom values, indicates a speed
value, and will change based on how far the control is
activated.
EN | 14
Number
0029
0014
0030
0038
0043
0044
0045
0046
1x53
0x51
1x52
0x54
1x41
0x42

Advertisement