Hold Down Functions; Keypad Led Indicators - Bosch CP700B Installer's Reference Manual

Solution graphic keypads
Table of Contents

Advertisement

Graphic Keypads
Installer Reference Guide

Hold Down Functions

Keypads support the following hold down function
when they have been assigned to an area. Emergency
key functions can be disabled if required to prevent
nuisance alarms.
See the Devices-Keypads & Readers-Emergency Keys
menu option in panel programming to disable these
features.
Hold Down Functions
Function
Enter a valid PIN and then press and
hold down the [ON] key, the system
All ON
will turn on or arm all areas that the
user belongs to at the same time.
Enter a valid PIN and then press and
hold down the [OFF] key, the system
All OFF
will turn off or disarm all areas that
the user belongs to at the same time.
Press and hold down the [4] key for
[4]
2 seconds to toggle chime mode on
or off.
Press and hold down the [6] key for
2 seconds to force the system to an-
[6]
swer an incoming PSTN RAS remote
session call.
Press and hold the [] and [] keys
down together for 2 seconds to trigger
[] + []
a Panic alarm. If programmed the
sirens will sound and the monitoring
station will be notified.
Press and hold the [] and [] keys
down together for 2 seconds to trigger
[] + []
a Fire alarm. If programmed the sirens
will sound and the monitoring station
will be notified.
Press and hold the [] and [] keys
down together for 2 seconds to trigger
[] + []
a Medical alarm. If programmed the
sirens will sound and the monitoring
station will be notified.
Table 5: Hold Down Functions
Figure 7: Keypad Emergency Alarm Triggers
6
Meaning

Keypad LED Indicators

Keypads includes green, blue and red LED's which pro-
vide visual feedback during system operation.
The green and red LED's indicators will show area and
alarm status and the blue LED will show the door status
depending how the keypad has been configured.
LED Operation For Area Control
Led
Condition
On
Red
Flashing
On
Green
Flashing
Red &
Both On
Green
Red On
Red &
and Green
Green
Flashing
Red &
Alternate
Green
Flashing
Red &
Flashing
Green
Red &
Both Off
Green
Table 6: Keypad LED's - Area Control
To have the keypad control an area on the alarm system
you need to assign the keypad to a home area. See the
Devices-Keypads-Home Area menu option in panel pro-
gramming. If alarm system control is not required then
you should set the home area option to No Area.
LED Function For Door Control
Led
Condition
Blue
On
Blue
Fast Flash
Continuous
Blue
Fast Flash
Blue
2 Flashes
Table 7: Keypad LED's - Door Control
Bosch Security Systems 03/16 Graphic Keypads BIRG FTR1.0
Meaning
Area All On
Area Alarm
Area is OFF
Area not ready to turn on -
zone(s) unsealed
Area armed in Part mode
and all zones sealed.
Area armed in Part mode
with zones unsealed.
Keypad initialising during
power up or LAN scan.
Installer programming
mode is active.
Home Area and Access
Group not programmed or
keypad not powered.
Meaning
Door Locked
Door Unlocked
Door manually unlocked
or overridden.
Door automatically
unlocked by schedule or
time zone

Hide quick links: