Remote �larm Reporting
Remote Cam Fail Reporting
Remote Startup Reporting
�RC �ing �nabled
�larm Responder �ort
Dial Retry Time (secs)
Dial Count
This must be enabled for the unit to automatically connect
on alarm.
�nabling this option ensures the unit reports camera failure on
any of the inputs to the R�RC.
This will send an alarm report when the unit starts up. �ny system
resets will be identified.
Should the modem�router at the �larm Recei�ing Centre be
dormant, the unit will '�ing' the �RC prior to sending reporting
data.
This specifies the network port number used for reporting to the
alarm ser�er. �n normal circumstances this should be left at the
default value (23).
�f the initial connection attempt fails, the unit will wait for the
specified time period (in seconds) before attempting to re-connect.
This identifies the number of times the unit will attempt to connect
after a failed attempt. � setting of '0' means no limit and the unit
will continue to try and connect until successful.