Protected Setup Page (Cont.)
System Recovery:
Channel Code
Channel Port
Level Port
Channel Code
Function Show example
FIG. 56
NOTE: When the Function Show feature is displayed, the Channel Port and Code will appear in yellow, the Address Port and Code in
green, and the Level Port and Channel Code in purple.
To reboot the panel:
1.
Access the Protected Setup page.
2.
Press the Reboot button.
3.
Wait until the panel completes its reboot.
4.
Log back into the Protected Setup page, if necessary.
To shut down the panel:
1.
Access the Protected Setup page.
2.
Press the Shutdown button.
3.
Disconnect any power source plugs or USB connections, if necessary.

Security Settings

The Security button on the Protected Setup page has three settings: Standard, Secure, and DoD. Pressing the button opens the
Panel Security Setting popup window (FIG. 57)
Panel Security Setting popup window
FIG. 57
Each of the settings has different features for touch panel security:
Security Prof ile Features
Standard: • Factory default, shipped in this configuration.
Secure:
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom - Instruction Manual
• Reset System Settings - Deletes all of the current configuration parameters on the panel (including IP
Addresses, Device Number assignments, Passwords, and other presets). This option invokes a
Confirmation dialog, prompting you to confirm your selection before resetting the panel.
• Remove User Pages - Removes all TPD4 touch panel pages currently on the panel, including the pre-
installed AMX Demo pages. This option invokes a Confirmation dialog, prompting you to confirm your
selection before removing the panel pages.
Note that the YES button on the Confirmation dialog is disabled for 5 seconds as additional protection
against accidentally resetting the panel or removing the panel pages.
0.20
BUTTON
0,8
0,50
Address Port
Address Code
• Default Protected Setup Password is "1988".
• Remote login uses Telnet.
• Default Protected Setup Password is "Amx1234!".
• Minimum password requirement is 8 characters with at least one numeric character.
• Remote login uses SSH.
• Remote login user name is "amx".
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15 minutes.
• Login and logout audit logging is enabled.
Protected Setup Pages