3.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑Engine shut down and starting disabled.
Putting into operation
Item
Lube oil system
Coolant circuit
Engine management system Check for fault messages.
38 | Operation | MS15027/02E 2015-04
Measure
Check oil level in oil storage tank (→ Page 174).
Check engine coolant level (→ Page 178);
Check mixture coolant level (→ Page 183)