MTU MS15027/02E Operating Instuctions page 75

12 v 4000 lx4; 16 v 4000 lx4
Table of Contents

Advertisement

1.4510.198 – Knock Sensor Error A7
Red alarm. Initiated by antiknock control.
Cause
No signal from this knock
sensor.
1.4510.199 – Knock Sensor Error A8
Red alarm. Initiated by antiknock control.
Cause
No signal from this knock
sensor.
1.4510.200 – Knock Sensor Error A9
Red alarm. Initiated by antiknock control.
Cause
No signal from this knock
sensor.
1.4510.201 – Knock Sensor Error A10
Red alarm. Initiated by antiknock control.
Cause
No signal from this knock
sensor.
1.4510.202 – Knock Sensor Error B1
Red alarm. Initiated by antiknock control.
Cause
No signal from this knock
sensor.
1.4510.203 – Knock Sensor Error B2
Red alarm. Initiated by antiknock control.
Cause
No signal from this knock
sensor.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
Corrective action
1. Check cabling.
2. Check sensor (tightening torque, damage), replace as
necessary.
MS15027/02E 2015-04 | Troubleshooting | 75