MTU MS15027/02E Operating Instuctions page 65

12 v 4000 lx4; 16 v 4000 lx4
Table of Contents

Advertisement

112519 – HIHI T-Exhaust B9
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
112520 – HIHI T-Exhaust B10
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
112601 – LOLO T-Exhaust A1
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
112602 – LOLO T-Exhaust A2
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
112603 – LOLO T-Exhaust A3
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too low in comparison with
weighted average.
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 162).
4. Check valve gear.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 162).
4. Check valve gear.
Corrective action
1. Check spark plug.
2. Check emission values.
3. Check ignition timing (→ Page 162).
4. Check valve gear.
MS15027/02E 2015-04 | Troubleshooting | 65

Advertisement

Table of Contents
loading

This manual is also suitable for:

20 v 4000 lx4

Table of Contents