MTU MS15027/02E Operating Instuctions page 104

12 v 4000 lx4; 16 v 4000 lx4
Table of Contents

Advertisement

1.4540.041 – TecJet Internal Fault
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.042 – Keyswitch State
Red alarm. Initiated by TecJet.
Cause
Keyswitch cabling missing.
1.4540.043 – Parameter Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.044 – Parameter Version Error
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.045 – Main EEP Read Fail
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.046 – Main EEP Write Fail
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
1.4540.047 – Reading Parameters
Red alarm. Initiated by TecJet.
Cause
Hardware not ready for
operation.
104 | Troubleshooting | MS15027/02E 2015-04
Corrective action
u Restart TecJet.
Corrective action
u Check cabling.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.
Corrective action
u Restart TecJet.

Advertisement

Table of Contents
loading

This manual is also suitable for:

20 v 4000 lx4

Table of Contents