MTU MS15027/02E Operating Instuctions page 70

12 v 4000 lx4; 16 v 4000 lx4
Table of Contents

Advertisement

112705 – HIHI T-Exhaust A5 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112706 – HIHI T-Exhaust A6 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112707 – HIHI T-Exhaust A7 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112708 – HIHI T-Exhaust A8 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112709 – HIHI T-Exhaust A9 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112710 – HIHI T-Exhaust A10 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
70 | Troubleshooting | MS15027/02E 2015-04
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).

Advertisement

Table of Contents
loading

This manual is also suitable for:

20 v 4000 lx4