MTU MS15027/02E Operating Instuctions page 62

12 v 4000 lx4; 16 v 4000 lx4
Table of Contents

Advertisement

112504 – HIHI T-Exhaust A4
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
112505 – HIHI T-Exhaust A5
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
112506 – HIHI T-Exhaust A6
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
112507 – HIHI T-Exhaust A7
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
112508 – HIHI T-Exhaust A8
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high in comparison with
weighted average.
62 | Troubleshooting | MS15027/02E 2015-04
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 162).
3. Check valve gear (exhaust valves do not close).