4.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑ Engine shut down and starting disabled.
Putting into operation
Item
Lube oil system
Coolant circuit
Engine management system Check for fault messages.
Measure
Check oil level in oil storage tank (→ Page 190).
Check engine coolant level (→ Page 194);
Check mixture coolant level (→ Page 200)
MS15027/04E 2017-08 | Operation | 41