MTU MS15027/02E Operating Instuctions page 83

12 v 4000 lx4; 16 v 4000 lx4
Table of Contents

Advertisement

1.4520.575 – MIC5 IPE Primary Open Cylinder 6
Yellow alarm. Initiated by MIC5.
Cause
Disruption in primary circuit of
cylinder 6 in firing order.
1.4520.576 – MIC5 IPE Primary Open Cylinder 7
Yellow alarm. Initiated by MIC5.
Cause
Disruption in primary circuit of
cylinder 7 in firing order.
1.4520.577 – MIC5 IPE Primary Open Cylinder 8
Yellow alarm. Initiated by MIC5.
Cause
Disruption in primary circuit of
cylinder 8 in firing order.
1.4520.578 – MIC5 IPE Primary Open Cylinder 9
Yellow alarm. Initiated by MIC5.
Cause
Disruption in primary circuit of
cylinder 9 in firing order.
1.4520.579 – MIC5 IPE Primary Open Cylinder 10
Yellow alarm. Initiated by MIC5.
Cause
Disruption in primary circuit of
cylinder 10 in firing order.
1.4520.580 – MIC5 IPE Primary Open Cylinder 11
Yellow alarm. Initiated by MIC5.
Cause
Disruption in primary circuit of
cylinder 11 in firing order.
1.4520.581 – MIC5 IPE Primary Open Cylinder 12
Yellow alarm. Initiated by MIC5.
Cause
Disruption in primary circuit of
cylinder 12 in firing order.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
MS15027/02E 2015-04 | Troubleshooting | 83