MTU MS15027/02E Operating Instuctions page 153

12 v 4000 lx4; 16 v 4000 lx4
Table of Contents

Advertisement

3.
Remove locknut (1).
4.
Remove filter cover (3) with washer (2).
5.
Carefully lift out fine filter (6).
6.
Carefully lift out coalescence filter (5).
7.
Clean sealing faces and inside of housing.
8.
Check condition of gaskets on new fine fil-
ter and new coalescence filter.
Note:
The fine filter (6) must be installed in the
correct position in the housing.
9.
Place fine filter (6) in housing, ensuring it is
straight.
Note:
The coalescence filter (5) must be installed
in the correct position in the housing.
10.
Place coalescence filter (5) in housing, en-
suring it is straight.
11.
Fit filter cover (3), ensuring it is positioned
correctly.
12.
Screw on washer (2) with new locknut (1) and tighten to specified tightening torque with torque wrench.
Name
Locknut
13.
Fit housing cover (1).
14.
Fit clamp (2) neatly and tighten to specified torque using a torque wrench.
Name
Clamp
Size
Type
Tightening torque
Size
Type
Tightening torque
Lubricant
Lubricant
MS15027/02E 2015-04 | Task Description | 153
Value/Standard
15 Nm
Value/Standard
5 Nm

Advertisement