MTU MS15027/02E Operating Instuctions page 85

12 v 4000 lx4; 16 v 4000 lx4
Table of Contents

Advertisement

1.4520.589 – MIC5 IPE Primary Open Cylinder 20
Yellow alarm. Initiated by MIC5.
Cause
Disruption in primary circuit of
cylinder 20 in firing order.
1.4520.590 – MIC5 IPE Prim Short Circuit Cyl 1
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 1 in firing order.
1.4520.591 – MIC5 IPE Prim Short Circuit Cyl 2
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 2 in firing order.
1.4520.592 – MIC5 IPE Prim Short Circuit Cyl 3
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 3 in firing order.
1.4520.593 – MIC5 IPE Prim Short Circuit Cyl 4
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 4 in firing order.
1.4520.594 – MIC5 IPE Prim Short Circuit Cyl 5
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 5 in firing order.
1.4520.595 – MIC5 IPE Prim Short Circuit Cyl 6
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 6 in firing order.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
MS15027/02E 2015-04 | Troubleshooting | 85

Advertisement

Table of Contents
loading

This manual is also suitable for:

20 v 4000 lx4

Table of Contents