RX CURVE
CURVE1 CH
:
02
TYPE :
CURVE2 CH
:
05
TYPE :
CURVE3 CH
:
04
TYPE :
Otherwise, the left and right ailerons have different
control characteristics.
With the RX CURVE function you can manage the
control characteristics for up to three servos:
CURVE 1, 2 or 3 CH
Select the desired control channel (INPUT CH) of the
fi rst servo.
The following setting in TYPE only pertains to the
channel selected here.
TYPE
Select the servo curve:
A: EXPO = -100 % and DUAL RATE = 125 %
The servo reacts strongly to movements of the
joystick around the neutral position. As the rudder
throw increases, the curve becomes fl atter.
B: Linear setting.
The servo follows the joystick movement linearly.
C: EXPO = +100 % and DUAL RATE = 70 %
The servo reacts weakly to the joystick movements
around the neutral position. As the rudder throw
increases, the curve becomes steeper.
Notice:
The control characteristics programmed here also affect
the mapped receiver outputs.
216 Detail program description - Control adjust
RX SERVO TEST
RX SERVO TEST
A
ALL–MAX
ALL–MIN
A
TEST
ALARM VOLT : 3.8V
B
ALARM TEMP+: 70°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
Value
ALL-MAX
ALL-MIN
TEST
ALARM VOLT Alarm threshold
ALARM
TEMP+
ALARM
TEMP–
CH OUTPUT
TYPE
: 2000μsec
: 1000μsec
: STOP
Explanation
Possible settings
Servo travel on
1500 ... 2000 µs
the "+" side for all
servo outputs for
the servo test
Servo travel on the
1500 ... 1000 µs
"-" side for all servo
outputs for the
servo test
Test procedure
START / STOP
3,0 ... 6,0 V
of the receiver
factory setting:
undervoltage
3.8 V
warning
Alarm threshold for
50 ... 80 °C
excessively high
Factory setting:
temperature of the
70 °C
receiver
Alarm threshold
-20 ... +10 °C
for excessively low
Factory setting:
temperature of the
-10 °C
receiver
Channel sequence ONCE, SAME,
SUMI, SUMO
ALL-MAX (servo travel on the "+" side)
In this line you set the maximum servo travel on the plus
side of the control travel for the servo test.
2000 µs corresponds to the full throw; 1500 µs
corresponds to the neutral position.
Make sure that the servos do not overrun mechanically
during the test routine.
ALL-MIN (servo travel on the "-" side)
You adjust the maximum servo travel on the minus side
of the control path for the servo test in this line.
1000 µs corresponds to the full throw; 1500 µs
corresponds to the neutral position.
TEST
You start and stop the servo test integrated in the
receivers in this line.
By pressing the central
SET
key of the right touch pad,
you activate the input fi eld:
RX SERVO TEST
ALL–MAX
: 2000μsec
ALL–MIN
: 1000μsec
TEST
:
STOP
ALARM VOLT : 3.8V
ALARM TEMP+: 70°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
With one of the arrow keys of the right touch pad, you
now select START:
RX SERVO TEST
ALL–MAX
: 2000μsec
ALL–MIN
: 1000μsec
TEST
:
START
ALARM VOLT : 3.8V
ALARM TEMP+: 70°C
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE