Smoothing the Channel 1 curve
In the example below, sample reference points have
been set:
Reference point 1 to 0%
Reference point 2 to +25%
Reference point 3 to -75%
as described in the last section.
C1 Cur ve
Cur ve
off
Input
–50%
Output
0%
Point
1
0%
Normal
This "jagged" curve profi le can be smoothed
automatically simply by pressing a button.
First – assuming a situation is confi gured as presented
above – tap the center
ESC
button on the left touch pad
to deactivate the value fi eld. Then use the arrow keys on
the left or right touch pad to move the marker frame in
an upwards direction to the "Curve" line. Now briefl y tap
the center
SET
key on the right touch pad to activate the
value fi eld on the "Curve" line:
C1 Cur ve
Cur ve
off
Input
–50%
Output
0%
Point
1
0%
Normal
Use the arrow keys on the right touch pad to set the
curve value from "off" to "on" and complete this setup
procedure by briefl y tapping the center SET the center
118 Detail program description - Control adjust
SET
key on the right touch pad or the center
on the left touch pad:
C1 Cur ve
Cur ve
on
Input
–50%
Output
0%
Point
1
0%
Normal
Note:
The curves shown here are for demonstration purposes
only and are not at all representative of real throttle/
airbrake curves. For real-world application examples,
see the programming examples from page 242 onwards.