HORIZONTAL VENT HEAT SHIELD INSTALLATION

IMPORTANT: THE HORIZONTAL VENT HEAT SHIELD MUST BE INSTALLED WHEN USING A 45-DEGREE ELBOW TO HORIZONTALLY
POSITION THE VENT SYSTEM. EXCEPTION: CORNER INSTALLATIONS
To Install Horizontal Vent Heat Shield:
1.
Loosen, but do not remove center three screws at back of fireplace as
shown.
2.
Bend horizontal heat shield at perforation to a 45° angle. Slide (3) slots
on horizontal vent heat shield under loosened screws. Re-tighten screws.
NAILING FLANGE ASSEMBLY & INSTALLATION
1.
Remove (4) nailing flanges from fireplace sides.
2.
With the 1/4" (6 mm) stand-offs on nailing flanges facing away from fireplace, align nailing flange with holes on outside corners of
fireplace. Secure with screws (provided in components packet) through slots in nailing flanges.
3.
Bend perforation on nailing flange until parallel with fireplace face. Do not bend toward fireplace face.
4.
Position framing stud against 1/4" (6 mm) stand-off (located on backside of nailing flange). Secure with nails or screws.
NOTE: Depending on facing material, tabs can be adjusted forward or back up to 1/2" (13 mm).
CAUTION: NEVER PERMANENTLY REMOVE THESE ASSEMBLIES FROM FIREPLACE - THEY MUST BE SECURED IN PLACE REGARDLESS OF
FINISH MATERIAL USED.
When installed, nailing flanges provide the minimum 1/4" (6 mm) clearance from fireplace sides.
AS SHIPPED
PREPARE THE FIREPLACE
NAILING FLANGES
INSTALLED
Attach here. Tighten screws.
1/4" (6mm)
CLEARANCE
PAGE 11
1/4" (6mm)
CLEARANCE
FRONT VIEW
NAILING FLANGE
FRAMING STUD
TOP VIEW
STAND-OFF
FRAMING STUD
NAILING FLANGE