3.9.6

Double Feed Control Settings

This screen enables to set the Double Feed Control
(DFC) settings for the different feeders on or off and
to set the thickness measurement.
To set the DFC for the different feeders:
1.
Press the
optional Thin Booklet Feeder.
2.
Press the
or off -
.
If the DFC is on you can set Continue on double on or off using the
Continue on double is on ("yes"), the machine will not stop if two sheets are feeded
instead of one. The document-set containing the double sheets will be diverted.
When a job is started, the first document taken per feeder is used for a reference
measurement. When a document is exceeding that reference thickness an error will be
displayed.
Note
When Daily mail is selected, the DFC will be switched off automatically.
To set the thickness measurement:
1.
Press the
2.
Press the
If the thickness measurement is on you can set the measurement area:
3.
Press the
4.
Set the measurement area using the arrow buttons and press the
The standard position of the measurement area is sufficient for a great variety of
documents. Only when using special types of documents, for example small cards, the
position of the measurement area might be adjusted.
When the set thickness is not corresponding the reference value an error will be displayed.