0BE1: Fan motor malfunction

Fan motor (FM1)
Step
Check the FM1 connector for proper con-
1
nection and correct as necessary.
Check FM1 for proper drive coupling and
2
correct as necessary.
3
FM1 operation check
4
FSCB replacement
4.2.8
133B: Communication malfunction
FS control board (FSCB)
Step
Check the FSCB connector for proper con-
1
nection and correct as necessary.
Check the PRCB connector for proper con-
2
nection and correct as necessary.
3
FSCB replacement
4
PRCB replacement
4.2.9

3FFB: Flash ROM malfunction

FS control board (FSCB)
Step
Disconnect and then connect the power
1
cord. Turn OFF the main switch, wait for 10
sec. or more, and turn ON the main switch.
2
The firmware data is overwritten.
3
FSCB replacement