Field Service Ver. 1.0 Apr. 2008
4.2.7
0BE1: Fan motor malfunction
Fan motor (FM1)
Step
Check the FM1 connector for proper con-
1
nection and correct as necessary.
Check FM1 for proper drive coupling and
2
correct as necessary.
3
FM1 operation check
4
FSCB replacement
4.2.8
133B: Communication malfunction
FS control board (FSCB)
Step
Check the FSCB connector for proper con-
1
nection and correct as necessary.
Check the PRCB connector for proper con-
2
nection and correct as necessary.
3
FSCB replacement
4
PRCB replacement
4.2.9
3FFB: Flash ROM malfunction
FS control board (FSCB)
Step
Disconnect and then connect the power
1
cord. Turn OFF the main switch, wait for 10
sec. or more, and turn ON the main switch.
2
The firmware data is overwritten.
3
FSCB replacement
Relevant electrical parts
Action
Relevant electrical parts
Action
Relevant electrical parts
Action
FS control board (FSCB)
WIRING DIAGRAM
Control signal
⎯
⎯
FSCB CN13-2 (LOCK)
⎯
Print control board (PRCB)
WIRING DIAGRAM
Control signal
⎯
⎯
⎯
⎯
WIRING DIAGRAM
Control signal
⎯
⎯
⎯
4. Error codes
Location
(electrical
component)
⎯
⎯
G-6
⎯
Location
(electrical
component)
⎯
⎯
⎯
⎯
Location
(electrical
component)
⎯
⎯
⎯
33