0F52: Toner Level Sensor/Y Malfunction; 0F53: Toner Level Sensor/M Malfunction; 0F54: Toner Level Sensor/C Malfunction; 0F55: Toner Level Sensor/K Malfunction - Konica Minolta Bizhub-C31P Service Manual

Table of Contents

Advertisement

Field Service Ver. 1.0 Apr. 2008
14.3.19

0F52: Toner level sensor/Y malfunction

14.3.20

0F53: Toner level sensor/M malfunction

14.3.21

0F54: Toner level sensor/C malfunction

14.3.22

0F55: Toner level sensor/K malfunction

Toner level sensor board (TLSB)
Step
Check the TLSB and PRCB for proper con-
1
nection and correct as necessary.
2
Change TLSB.
3
Change PRCB.
14.3.23
133B: Finisher communication malfunction
FS control board (FSCB)
Step
1
Reboot the main body.
2
Change FSCB.
3
Change PRCB.
14.3.24

13C0: Print control board malfunction

Print control board (PRCB)
Step
1
Reboot the main body.
2
Change PRCB.
Relevant electrical parts
Action
Relevant electrical parts
Action
Relevant electrical parts
Action
Print control board (PRCB)
WIRING DIAGRAM
Control signal
Print control board (PRCB)
WIRING DIAGRAM
Control signal
WIRING DIAGRAM
Control signal
14. Malfunction code
Location (electri-
cal component)
Location (electri-
cal component)
Location (electri-
cal component)
213