11. SERVICE MENU
Conversion method from hexadecimal number to binary number
1. The hexadecimal number (four digits) is converted in each digit based on the following
table.
Hexadeci-
Binary
mal number
number
0
0000
1
0001
2
0010
3
0011
2. Match the converted numerical value of four digits, then two head digits are excluded
and it is assumed the binary number of 14 digits.
(2) EVENT LOG
Functions
• To print the EVENT LOG.
Use
• To check the jams/troubles which occurred, and the history of replacing the consum-
ables.
The items which can be checked are as follows.
Paper Jam Error
Engine Fatal Error : The history of the troubles which required service call
Fuser Unit
Transfer Belt
Second Trans
Toner Cartridge
Imaging Unit
Trouble Counter
Setting/
1. Select [EVENT LOG] and press the Menu/Select key.
Procedure
2. Select [PRINT] and press the Menu/Select key.
(3) CONFIGURATION PG
Functions
• Prints the information concerning the Configuration.
Use
• To check the adjustment values set by the Maintenance Menu and Service Menu.
The items which can be checked are as follows.
TOP ADJUSTMENT
LEFT ADJUSTMENT
LEFT ADJ DUPLEX
TRANSFER POWER
IMG ADJ THICK
IMG ADJ BLACK
IMAGE ADJ PARAM
MAXIMUM DENSITY
FUSER CONTROL
Setting/
1. Select [CONFIGURATION PG] and press the Menu/Select key.
Procedure
2. Select [PRINT] and press the Menu/Select key.
188
Hexadeci-
Binary
mal number
number
4
0100
5
0101
6
0110
7
0111
: The number of times jam have occurred and its history
: The history of replacing the fuser unit
: The history of replacing the transfer belt
: The history of replacing the transfer roller
: The history of replacing the toner cartridge
: The history of replacing the imaging unit
: Trouble counting for each section
Field Service Ver. 1.0 Apr. 2008
Hexadeci-
Binary
mal number
number
8
1000
9
1001
A
1010
B
1011
Hexadeci-
Binary
mal number
number
C
1100
D
1101
E
1110
F
1111