Konica Minolta Bizhub-C31P Service Manual page 241

Table of Contents

Advertisement

14. Malfunction code
LCD1
LCD2/LCD3
(service
(error
call ID)
description)
0510
FUSER
ERROR
0511
FUSER
ERROR
0520
FUSER
ERROR
0521
FUSER
ERROR
0B30
FINISHER
ERROR
0B47
FINISHER
ERROR
0B48
FINISHER
ERROR
0B4A
FINISHER
ERROR
0B4C
FINISHER
ERROR
0BA0
FINISHER
ERROR
0BE1
FINISHER
ERROR
0F52
TE
SENSOR Y
0F53
TE
SENSOR M
0F54
TE
SENSOR C
0F55
TE
SENSOR K
133B
FINISHER
COMMUNI-
CATION
13C0
ENGINE
H/W
ERROR
13E2
FLASH
WRITE
204
Item
Abnormally low heating
• The temperature detected by the thermistor/1
roller temperature
Abnormally low fusing
• The temperature detected by the thermistor/2
pressure roller
temperature
Abnormally high heat-
• The temperature detected by the thermistor/1
ing roller temperature
• The heater lamp remains ON for a given period of
Abnormally high fusing
• The temperature detected by the thermistor/2
pressure roller
temperature
Finisher aligning plate
See P.29 of the staple finisher service manual.
drive malfunction
Finisher media holding
drive malfunction
Finisher exit roller pres-
sure/retraction mal-
function
Finisher aligning belt
pressure/retraction
malfunction
Finisher media ejector
motor malfunction
Finisher tray up/down
motor ascent/descent
drive malfunction
Finisher fan motor mal-
function
Toner level sensor/Y
• An error occurs on the toner level sensor board
malfunction
Toner level sensor/M
malfunction
Toner level sensor/C
malfunction
Toner level sensor/K
malfunction
Finisher
• A communication error occurs between the main
communication error
Print control board mal-
• A communication error occurs in print control board
function
Flash ROM write error
• Flash ROM writing is found faulty during a check.
Field Service Ver. 1.0 Apr. 2008
Detection timing
remains lower than the specified value for a given
period of time or longer.
remains lower than the specified value for a given
period of time or longer.
remains higher than the specified value for a given
period of time or longer.
time or longer.
remains higher than the specified value for a given
period of time or longer.
(TLSB).
body and the finisher.
(PRCB).

Advertisement