5. Other
5.3.9

Operation key board (OKB)

[2]
[1]
[1]
[3]
36
[1]
4139F2C613DA
[3]
[4]
4139F2C663DA
[2]
[1]
4139F2C665DA
Field Service Ver. 1.0 Jul. 2006
1. Open the IR unit.
2. Remove the three caps [1].
3. Remove three screws [1].
4. Disconnect two connectors [2] and
remove the ground wire [3]. Then,
remove the control panel [4].
5. Remove four screws [1], the bracket
[2], and the operation key board [3].