20. Remove two screws [1] and remove
the fusing unit [2].
21. To reinstall, reverse the order of
removal.
CAUTION
• Make sure that the docking gear
shaft of the fusing unit fits in the
hole of the fusing frame.
• When reinstalling the left cover
after reinstalling the fusing unit,
make sure that the harness of the
fusing unit is located below the rib
of the left cover.