11.4.3

CCD MAIN ZOOM

• To adjust for variations in the accuracy of IR parts and their mounting accuracy by
Function
varying the scanning zoom ratio in the main scanning direction.
• When the Scanner unit has been replaced
NOTE
Use
• After the [PRN MAIN REGIST] and [PRN SUB REGIST] adjustments have been
performed
• Adjust the width of D in the copy of the test pattern1 so that the following specification
is met.
• 100 ± 0.5% (Zoom Ratio = Full Size:100%)
Adjustment
Specification
Adjustment
• -2.0% ~ "0%" ~ +2.0%
Range
• Step: 0.4%
1. Print the test pattern1.
See P.130
2. Enter the [2. ADJUST] menu in the service mode.
3. Select [CCD MAIN ZOOM] of [2. ADJUST] and press the Menu Select key.
4. Place the test pattern1 on the Original Glass and make a test copy.
NOTE
• The test pattern1 should be positioned vertically.
Setting/
• Use A4 or Letter paper loaded into tray1 to make the test copy.
Procedure
5. Check that the width of D in the copy of the test pattern1 meets the specification.
Calculation: (1 - Width of D in the document ÷ Width of D in the copy) × 100
If the width of D is out of specification, adjust it according to the following procedure.
6. Press the Menu Select key.
7. Using the
8. Place the test pattern1 on the Original Glass. Then, make a test copy again and check
it.
• If the width of D in the test pattern is longer than the specified width
Adjustment
..... Decrease the setting.
Instructions
• If the width of D in the test pattern is shorter than the specified width
..... Increase the setting.