Soft Switch: #21 - Konica Minolta magicolor 2490MF Service Manual

Hide thumbs Also See for magicolor 2490MF:
Table of Contents

Advertisement

Field Service Ver. 1.0 Jul. 2006
12.3.21

SOFT SWITCH: #21

Bit No.
Designation
NSS signal before
8
DCS
7
CNG sending duration
after dialing
6
5
T4 timer
4
Reserved
3
DIS signal length
2
Increase default T1
Timing during calling
(Only for TX function)
1
• Bit 1 to 2: T1 indicate the calling time after dialing, can adjust the T1 time more long by change the
default value. The default T1 timer depends on each country regulation.
• Bit 3:
Some old machine can not accept DIS command over 4 bytes, and every time will become
fail. In this case can set this bit to 1. If this bit set to 1, JBIG and V8 capability will disable
automatically.
• Bit 8:
Sender machine's name will show on the other party's LCD or print on the report if remote
side is the same model.
Function
0: Not to send NSS signal for self mode in TX mode
1: Send NSS signal if remote side is same model
Duration (unit=sec)
40
Bit No. 7
Bit No. 6
0: 3.0 sec. Normal case
1: 4.5 sec.
Reserved
0: Normal length (Bit 1 to 64)
1: 4 bytes DIS command. bit 1 to 32 only
Description (sec)
T1
Bit No. 2
0
Bit No. 1
0
12. SOFT SWITCH set
60
70
120
0
0
1
0
1
0
T1+ 30
T1+ 40
T1+60
0
1
1
0
Initial
Setting
Bit
HEX
1
0
8
1
1
0
0
0
0
0
0
1
1
0
185