18. FAX error
Code
Line energy over threshold lasts for 60 seconds after MCF and can not detect FSK or carrier
004A
signal in ECM mode.
004B
Can not detect correct FSK signal even though detected FSK tone within 6 sec.
004C
Handshake fail during re-train or between page in V34 RX.
004E
Receive DCN signal after sending DIS in V.34.
004F
Remote side disconnected after sending ANSam in V.8 phase.
0050
Did not receive any correct signal after sending CJ signal in V.8 phase.
0051
Did not receive phase 3 signal after phase 2 within 20 seconds in V.34.
0052
Did not receive phase 4 signal after phase 3 within 20 seconds in V.34.
0053
Modem disconnect after phase 4 in V.34.
0054
Remote side disconnected after phase 4 in V.8.
0055
Receive incorrect signal after sending DIS signal in V.34.
0056
Modem disconnect after sending CFR in V.34.
0057
Did not detect image signal within 6 seconds after sending CFR.
0058
Did not detect image signal within 6 seconds after modem enter to primary phase in V.34.
005A
Modem can not detect any correct ECM frame within 3 minutes in phase C.
005B
Did not detect phase 5 signal after primary channel within 6 seconds.
005C
Detect busy tone within control channel after phase C.
005D
Modem can not detect any correct ECM frame with 12 Sec in phase C.
005E
Did not detect control channel signal after received RCP frame within 6 seconds.
005F
Did not detect silence after sending JM signal for polling TX function.
0060
There are no bulletin files to be polled in V.34.
0061
Machine can not detect V.21 or V.8 signal within 35 seconds.
0062
Modem disconnect in phase D after our side sending out flag sequence in control channel.
0063
Did not receive any flag sequence in control channel within 6 seconds in phase D.
Did not detect any control channel signal in phase D within 60 seconds even though energy
0064
still on the line.
0065
Did not detect any control channel signal within 60 seconds after detect silence in phase D.
0066
Did not receive T.30 signal or carrier signal after sending CFR in V.34.
0070
User presses stop key during receiving.
0071
Memory full during receiving.