Field Service Ver. 1.0 Jul. 2006
[1]
[3]
4139fs2068c2
[2]
[1]
4139F2C593DA
[1]
[2]
4139F2C594DA
Precautions for reinstallation of the
safety switch assy
• Check that the switch is actuated
with the front cover and the Upper
Cover closed.
• Make sure that the distance
between the switch lever and
switch case (with the switch in the
actuated position) falls within the
specified range.
Specifications: 0.1 to 1.0 mm
5. Remove four screws [1] and the rack
drive assy [2].
6. Remove two screws [1], disconnect
the connector [2], and remove the
developing motor [3].
5. Other
63