18. FAX error
Code
00BC
Modem not ready within 10 second after entering primary channel in V.34.
00BD
Can not detect correct V.21 or JM signal after detected FSK frequency.
00BE
Remote side no document to be polled after V8 handshaking.
00BF
Capability not match after V8 handshaking.
00C0
Remote side disconnect before entering primary channel in V.34.
At phase-D, transmitting unit sends out EOP 3 times consecutively, but receives no answer
00C1
from receiving unit.
00C2
Remote side disconnect after sending out V.8 CM signal.
00C4
After sending MPS signal, the received signal is not one of MCF, RTN, PIP, PIN, RTP, DCN.
00C5
Received DCN signal after sending MPS signal.
00C9
At phase-D, sending MPS 3 times consecutively, but no answer from receiving unit.
After sending EOP signal, the received signal is not one of MCF, RTN, PIP, PIN, PRI-EOP,
00CA
DCN.
00CB
After sending EOP signal, the received signal is DCN signal.
00CC
After sending EOM signal, the received signal is not one of MCF, RTN, PIP, PIN, RTP, DCN.
00CD
At phase-D, transmitting unit sends out EOM 3 times consecutively, but receives no answer.
00CE
At phase-D, transmitting unit sends out EOM, but receives DCN.
00CF
Received incorrect signal after sending DTC signal for V.34 polling.
00D0
Received ERR signal after sending EOR_NULL.
00D1
Received incorrect response after sending PPS_EOP signal in V.34.
00D2
Receive DCN after send command PPS_EOP signal.
00D3
Received DCN after sending PPS_NULL signal.
00D4
Received DCN after sending PPS_EOM signal.
00D8
Did not detect correct phase 3 signal for polling within 25 seconds.
00D9
Did not detect correct phase 3 signal after detecting silence after phase 2.
00DA
Did not detect phase 4 signal within 30 seconds or remote side hang up over 6 seconds.
00DB
Did not receive any T.30 signal within 15 seconds in phase 4.
00DC
Received T.30 signal in phase 4 other than DCS, DIS or DTC.
00DE
Remote side no SUB capability in V.34.
At phase-D, transmitting unit sends out PPS_NULL 3 times consecutively but receives no
00E0
answer.
00E1
Received incorrect response after sending PPS_NULL.
00E2
Did not receive any response in RR response procedure after sending PPS_NULL.
00E4
At phase-D, transmitting unit sends out PPS_MPS 3 times consecutively but no answer.
00E5
Received incorrect response after sending PPS_MPS.
00E6
Did not receive any response in RR response procedure after sending PPS_MPS.
00E7
Received DCN after sending PPS_MPS.
00E8
At phase-D, transmitting unit sends out PPS_EOP 3 times consecutively but no answer.
00E9
Receive PIN signal after sent last page three times.
00EA
Did not receive any response in RR response procedure after sending PPS_EOP.
00EB
At phase-D, transmitting unit sends out PPS_EOM 3 times consecutively but no answer.
00EC
Received incorrect response after sending PPS_EOM.
00ED
Did not receive any response in RR response procedure after sent out PPS_EOM.