6.2.2 Holder Lower Limit Sensor Adjustment
Fit the upper limit sensor to the sensor
mounting plate (lower) [7], and temporarily
secure it in place using 2 screws. Execute
holder motor test in service mode to move
the holder slide plate [9] to its lower limit.
(For details, see the section 2.5 in the ser-
vice mode chapter.)
With the holder slide plate [9] at its lower
limit, open the stacker cover, and insert a
screwdriver or the like through the detection
slit [10] of the stacker cover sensor to keep
it in place.
Adjust the position of the sensor mount-
ing plate (lower) [7] so that the distance be-
tween each top edge of the delivery guide
and the holder sheet inside the stacker is 4
± 1 mm; then, tightly secure it in place us-
ing 2 screws.
COPYRIGHT© 2002 CANON INC.
2000
CANON BOOKLET TRIMMER-A1 REV.0 FEB. 2002
CHAPTER 3 MECHANICAL SYSTEMS
[9]
F03-602-03
F03-602-04
F03-602-05
[7]
[10]