Second Label
Rotary Parameter
Rotary Graph
Level Meter
N–X or AUX Send Level Indication:
Overload Indication, Analog Inputs: As soon as one sample at an analog input reaches full scale modulation, the
Overload Indication, Digital Inputs: Full scale modulation at a digital input is not considered to be an overload – it
Overload Indication, REC/PGM Outputs:
Auto Take-Over Indication:
Gain Reduction Meter
OLED Display, Local View Mode
Document generated: 06.08.14
The 2nd label area is used exclusively for indication of the I/O sharing
producer system name. It is blanked as long as the rotary is touched, except
during input channel routing.
The rotary parameter area indicates the parameter name if a rotary function
is assigned to this channel.
The rotary graph area shows a graphical representation of the value of the
assigned rotary function.
A small bar graph input level meter is provided in each channel's OLED
display, either indicating the input level, or the N–X or AUX send level of
the channel (configurable). The value indicated on the meter is depending on
the console's headroom setting (default value: 0 dB indication for –9 dB
In this mode the level meter indicates the N–X or the AUX send level of the
channel.
overload indicator is on for approx. 300 ms (the idea is that the probability
of an A/D converter reaching full scale without clipping is close to zero. Any
full scale levels within the path are considered to be overloads).
is simply the output level of a source.
If one sample of an output signal reaches full scale, the corresponding over-
load indication is on for approx. 300 ms.
The physical value and the internal, processed value of the fader may be dif-
ferent. This can be the case after routing, snapshot, or CAB changes. If the
values are different, auto take-over mode is enabled. The channel display
indicates by FDR UP or FDR DOWN in which direction the fader knob
has to be moved. As soon as the fader knob has been moved a bit, the display
changes to a numerical value, such as -15 UP or 27 DOWN. When the
fader position matches the internal value, TAKEOVER flashes three times;
the whole process is quite self-explanatory.
The meter is able to indicate either Compressor/Limiter gain reduction,
DeEsser gain reduction or the channels voice mix control gain (if VoiceMix-
option is available). Softbuttons on an attached DVI screen allow selection
of the desired indication.
Local view mode is also referred to as 'Mini Vistonics' view. When pressing,
e.g., the EQ key in the central section's FUNCTION area, it is illuminated in
red. If selecting now any of the channels by pressing its SEL key, the light
bars at the bottom of the channel OLED displays are illuminated in red as
well. Only this channel's label is displayed, and its SEL key is illuminated
now. All other channel labels are blanked, so that the user clearly sees what
he adjusts and in which channel. The parameters of this particular channel are
displayed on the OLED displays and can be adjusted with the corresponding
rotary encoders. The different parameters can be switched on or off using the
corresponding
keys. Inactive parameters are indicated by greying them
out. If a complete parameter set such as the EQ section can also be switched
on/off as a whole, always the
If a function has more than six parameters – such as the EQ or DYN sections
– pressing its oval key successively toggles through all available parameter
'pages'. This whole process is very intuitive, just have a go with it!
SW V6.0
OnAir 1500 Digital Mixing Console
key at the far right is used for this purpose.
Operating Elements 4-5
).