Firmware Page - Studer OnAir 1500 Operating Instructions Manual

Hide thumbs Also See for OnAir 1500:
Table of Contents

Advertisement

FDR Start Trigger Point
5.12.8.3

Firmware Page

Update Firmware
Document generated: 06.08.14
Please note that it is recommended to perform this calibration for all faders
of a fader module at a time.
First, move all faders not to be calibrated to their –20 dB position (this posi-
tion is ignored during calibration).
Center the fader knobs to be calibrated between the –∞ and the –60 markers.
This will be the point where the fader start output is triggered after calibration.
Click on the FDR Start button. To check, close the faders that just have been
calibrated; the corresponding fader bars on the screen should disappear.
If you intend to calibrate the second fader module, click on the Fader Cal
menu button again and select it.
On this page, the version number of all software modules of the console is
displayed for reference. A module is selected using the rotary encoder just
below the Firmware field.
Note:
A complete set of firmware for all console modules is saved in the console's
memory. After having replaced a module by one that has been e.g. in the
spare parts stock for some time, its firmware might not be up-to-date with
the ones of the other console modules. Therefore it is recommended to check
whether the firmware versions correspond. If not, the current version may be
downloaded from the console to the module using the Update Firmware
function.
Select a module as described above; if its firmware can be updated, the
Update Firmware button appears at the right of the list. The module's
firmware will be updated when clicking on the Update Firmware button.
SW V6.0