ZyXEL Communications ZyWall 10W User Manual page 426

Zywall series internet security gateway
Hide thumbs Also See for ZyWall 10W:
Table of Contents

Advertisement

ZyWALL Series Internet Security Gateway
FIELD
Fail Tolerance
Enter the number of times your ZyWALL may attempt and fail to connect
to the Internet before traffic is forwarded to the backup gateway. Two to
five is usually a good number.
Period (sec)
Enter the time interval (in seconds) between WAN connection checks.
Five to 60 is usually a good number.
Timeout (sec)
Enter the number of seconds the ZyWALL waits for a ping response from
the IP Address in the Check WAN IP Address field before it times out.
The number in this field should be less than the number in the Period
field. Three to 50 is usually a good number.
The WAN connection is considered "down" after the ZyWALL times out
the number of times specified in the Fail Tolerance field.
When you have completed this menu, press [ENTER] at the prompt "Press [ENTER] to confirm or [ESC]
to cancel" to save your configuration or press [ESC] to cancel and go back to the previous screen.
28-14
Table 28-6 Menu 11.6: Traffic Redirect Setup
DESCRIPTION
EXAMPLE
2
5
3
Remote Node Setup

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zywall 30wZywall 100Zywall 50

Table of Contents