4-18 Configuring Your EcoPowerGateway
Option
Parameter
Thermal Sensor
Disabled
[Enabled]
BMC IRQ
Disabled
[IRQ 11]
Post Error Pause Disabled
[Enabled]
AC-LINK
Stay Off
[Last State]
Power On
Power ON Delay
[20] - 255
Time (Sec)
Platform Event
Disabled
Filtering
[Enabled]
The table below shows the operation when the DC power to the EcoPowerGateway is turned off
once and then on again, depending on the setting of "AC-LINK".
When the DC power to the EcoPowerGateway is turned on, the standby power is supplied to the
Maintenance Card.
System status before DC power off of
EcoPowerGateway
Operating
Aborting (power of the Maintenance Card being off also)
Forced shutdown
* Press the Maintenance switch continuously at least four seconds. This forcibly turns off the
power.
Description
Specify whether the temperature sensor
monitoring feature is enabled or disabled. If a
thermal error is detected with this item being
set to "Enabled", the system stops at the end
of POST.
Specify whether to assign IRQ for BMC
(Baseboard Management Controller).
Specify whether POST is aborted once at the
end of POST if an error occurs during the
execution of POST.
Specify the AC-LINK feature. Shows the
system status when the AC power is supplied
again to the EcoPowerGateway. See the
table below.
Specify the power-on delay time between 20
and 255 seconds. This option is available
only when "Power On" or "Last State" is
specified for AC LINK.
Specify whether the Platform Event Filtering
feature of the Baseboard Management
Controller (BMC) is enabled or disabled.
Setting of AC-LINK
Stay Off
Last State
Off
On
Off
Off
Off
Off
Your Setting
[
]: Factory-set
Power On
On
On
On