Advertisement

3.
Connect the EcoPowerGateway with the server unit or Module Enclosure.
The cable connectors have locking mechanism. Make sure that the cable connector is
surely locked.
Module enclosure
IMPORTANT: Incomplete locking of DC cable connector may cause
power leakage, electric shock due to the spark, hardware failure as well
as malfunction of the EcoPowerGateway.
4.
Push the DC output switch to the end.
Make sure that the DC output lamp goes on green.
Rear of the EcoPowerGateway
EcoPowerGateway
K410-213 DC cable
Insert the connector to the
end until it clicks.
To disconnect the connector,
push both sides of the
connector with your fingers
to unlock the connector, as
shown in the figure.
DC output switch
The DC output switch is a latch-type
pushbutton switch and equipped on
every four output ports.
DC output ON: Concave
DC output OFF: Convex
DC output lamp
General Description 2-13
DC power output ON: Lit green
DC power output OFF: Unlit