Error Messages On Virtual Lcd - NEC Express5800/T120a-E N8100-1531F User Manual

Table of Contents

Advertisement

8-22 Troubleshooting

Error Messages on Virtual LCD

NEC EXPRESSSCOPE Engine 2 (Remote Management Controller) on your server board allows
you to monitor the server status on the Web browser.
Example:
Message send from BIOS
Message send from BMC
Messages displayed on upper line (BIOS message)
On-screen message
XX BIOS Rev XXXX
Prepare To Boot
Mem Reconfigured
Mem Err Disable
CPU Reconfigured
Memory C-Err XX
Memory U-Err XX
PCI Bus SERR XX
PCI Bus PERR XX
Chipset Err XXXX
Messages displayed on lower line (BMC message)
On-screen message
Proc 1 VccpAlm
Proc 2 VccpAlm
BB P_Vtt Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +1.9vs Alm XX
BB +3.3v Alm XX
BB +3.3vs Alm XX
BB +5.0v Alm XX
BB +5vs Alm XX
BB +12v Alm XX
VBAT Alm XX
Description
POST in progress.
POST completes normally.
POST completes with memory degraded.
A correctable memory error frequently
occurred.
POST completes with processor
degraded.
A correctable error frequently occurred.
An uncorrectable error has occurred.
A SERR has occurred in the PCI bus XX.
A PERR has occurred in the PCI bus XX.
A chipset error occurred.
Description
Voltage alarm occurred
XX=09: high voltage (alarm)
XX=02: low voltage (alarm)
XX=07: high voltage (warning)
XX=00: low voltage (warning)
Virtual LCD
POWER ON
ATTENTION
Action
Wait until POST completes.
Wait until Boot completes.
Contact your service
representative.
Action
Contact your service
representative.
Status indicators

Advertisement

Table of Contents
loading

Table of Contents