Error messages on virtual LCD

NEC EXPRESSSCOPE Engine 2 (Remote Management Controller), which is on your server board,
allows you to monitor the server status from a Web browser running on a client PC via a network.
The virtual LCD (16 digits x 2 lines) in the "Host Information" area displays the POST codes and
status message.
When POST detects an error, the POST error code is displayed on the virtual LCD upon completion
of POST. See the table for POST error codes for details.
Example:
Message s ent from BIOS
Message sent from BMC
Messages displayed on top line (BIOS messages)
On-screen message
XX BIOS Rev YYYY
Prepare To Boot
CPU1_DIMM C-Err
CPU2_DIMM C-Err
Mem Err Disable
Mem Reconfigured
PCI Bus SERR XX
PCI Bus PERR XX
Description
POST in progress.
XX: POST code, YYYY: BIOS version
POST completes normally.
A correctable error occurred on one of
CPU1_DIMMs.
A correctable error occurred on one of
CPU2_DIMMs.
A correctable memory error frequently
occurred.
The system is running with memory
degraded.
A SERR has occurred in the PCI bus
XX.
A PERR has occurred in the PCI bus
XX.
Virtual LCD
POWER ON
ATTENTION
Wait until POST completes.
Wait until booting up completes.
The error was corrected. You
may continue operating the
server.
Contact your service
representative.