Error Messages on Virtual LCD

NEC EXPRESSSCOPE Engine 2 (Remote Management Controller) on your server board allows
you to monitor the server status on the Web browser.
Messages displayed on upper line (BIOS message)
On-screen message
XX BIOS Rev XXXX
Prepare To Boot
Mem Reconfigured
Mem Err Disable
CPU Reconfigured
Memory C-Err XX
Memory U-Err XX
PCI Bus SERR XX
PCI Bus PERR XX
Chipset Err XXXX
Messages displayed on lower line (BMC message)
On-screen message
Proc 1 VccpAlm
Proc 2 VccpAlm
BB P_Vtt Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +1.9vs Alm XX
BB +3.3v Alm XX
BB +3.3vs Alm XX
BB +5.0v Alm XX
BB +5vs Alm XX
BB +12v Alm XX
VBAT Alm XX
Description
POST in progress.
POST completes normally.
POST completes with memory degraded.
A correctable memory error frequently
occurred.
POST completes with processor
degraded.
A correctable error frequently occurred.
An uncorrectable error has occurred.
A SERR has occurred in the PCI bus XX.
A PERR has occurred in the PCI bus XX.
A chipset error occurred.
Description
Voltage alarm occurred
XX=09: high voltage (alarm)
XX=02: low voltage (alarm)
XX=07: high voltage (warning)
XX=00: low voltage (warning)
Troubleshooting 8-25
Action
Wait until POST completes.
Wait until Boot completes.
Contact your service
representative.
Action
Contact your service
representative.