Installing and Removing EX4300 Switch Hardware Components

Copyright © 2015, Juniper Networks, Inc.
Insert the mounting screws in the wall. Insert the top pair of mounting screws
3.
474.35 mm apart, and insert the second pair of mounting screws 151.81 mm directly
below the first set.
If the mounting screws are inserted in a wall board with no stud behind it, you must
use dry wall anchors rated to support 75 lb (34 kg). Insert the screws into wall studs
wherever possible to provide added support for the chassis.
Drive the screws only part way in, leaving about 1/4 in. (6 mm) distance between the
head of the screw and the wall. Use the screwdriver to drive the screws in.
Grasp each side of the switch or switches, lift the switch or switches, and hang the
4.
brackets from the mounting screws (see the representation in

Figure 48: Mounting the Switch on a Wall

Rear panel
Hang attached brackets
on wall-mounted screws.
Tighten the mounting screws by using the screwdriver.
5.
Connecting AC Power to an EX4300 Switch on page 173
Connecting DC Power to an EX4300 Switch on page 176
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 205
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 208
Wall-Mounting Warning for EX4300 Switches on page 282
The EX4300 switch chassis is a rigid sheet-metal structure that houses the hardware
components. The field-replaceable units (FRUs) in EX4300 switches are:
Power supplies
Fan modules
Chapter 11: Installing the Switch
Figure 48 on page
Front
panel
165).